110kV Substation AC Withstand Resonant Test

Original
price: Negotiable
minimum:
Total supply:
Delivery term: The date of payment from buyers deliver within days
seat: Hubei
Validity to: Long-term effective
Last update: 2020-09-11 03:55
Browse the number: 475
inquiry
Company Profile
 
 
Product details

Output Voltage:

0-1000kV

Output Frequency:

30-300HZ

Waveform:

Sine Wave

Quality Factor:

30-90

Power Supply:

220V/380V

Instability:

< 0.05%

High Light:

AC resonant test system,resonance test series


Customized Solution Test Equipment AC High Voltage Resonant Test System For Substation

This series devices are designed for AC withstand voltage test of substation primary equipment under 550KV or below, mainly composed of variable-frequency power supply, exciting transformer, reactor and capacitive Voltage divider


Features:

Easy to operate, two working modes: manual and automatic.

Can set Test Voltage, frequency range, protective current and operating time.

Smaller size, lighter weight compared with same voltage level same capacity reactor.

Small temperature rise at rated load. Strong protection, good stability. Multiple functions, cost effective.

Dry type epoxy cast, high mechanical strength, good insulation, nice and reliable.

Adjustable capacity of frequency control source.

With 220V or 380V single phase power, convenient for on-site power sourcing.

Flexible configuration. Different type reactors for option to meet different test object requirements.


Parameter:

Rated output voltage: 0 - 1000kV, output frequency: 30 ~ 300Hz.Waveform: pure sine wave, THD <1.0%.

Duty Cycle: Continuous working time 60mins one time at full power output.

Quality factor: 30-90. Frequency adjustment sensitivity: 0.1Hz, instability <0.05%.

Power Supply: 380/220V±15%, 50Hz ± 5%.

Model#

Apply to AC voltage withstand test for substation equipment at 10kV~500kV (frequency 30~300Hz)

Variable Frequency source

Reactor

Exciting Transformer

Capacitive Divider

Application scope

1set

As below

1set

1set

ZXBXZ-50/50/25

3kW

25kV/2 sets Dry Type

3kVA Dry Type

50kV

1000kV or below /10kV Power Transformer 10kV Circuit breaker,bus bar,PT,CT 10kV(300mm2) cable ≤1km

ZXBXZ-108/108/27

5kW

27kV/1A 4sets Dry Type

5kVA Dry Type

110kV

31500kvA or below /35kV Power Transformer 35kVCircuit breaker,bus bar,PT,CT 35kV(300mm2)cable≤0.5km 10kV(300mm2)cable≤2.0km

ZXBXZ-200/200/50

10kW

50kV/1A 4sets Dry Type

10kVA Dry Type

200kV

50000kVA or below/110kV Power Transformer 110kV GIS,PT,CT(for preventive Trial) 35kV(300mm2)cable≤1.0km 10kV(300mm2)cable≤2.5km

ZXBXZ-270/270/45

15kW

45kV/1A 6sets Dry Type

15kVA Dry Type

300kV

50000kvA or below/110kV Power Transformer 110kV GIS,Circuit Breaker,PT,CT etc 35kV(300mm2)cable≤1.2km 10kV(300mm2)cable≤3.0km

ZXBXZ-800/400/50

30kW

50kV/2A 8sets Dry Type 100kV 2A 4sets Oil-immersed type

30kVA Dry Type 30kVA Oil-immersed type

400kV

80000kvA or below /220kV Power Transformer 50000kvA or below /110kV Power Transformer 110/220kV GIS,PT,CT etc 35kV(300mm2)cable≤2.0km 110kV(400mm2)cable≤0.7km

ZXBXZ-1600/800/200

60kW

200kV/2A 4sets Oil-immersed type

60kVA Dry Type

800kV

80000kvA or below/220kV Power Transformer 50000kvA or below/110kV Power Transformer 500kV GIS,PT,CT etc 220kV Circuit Breaker,GIS,PT,CT etc 110kV(400mm2)cable≤1.5km 220kV(400mm2)cable≤1.0km


Tag:

AC resonant test system, hipot test equipment, resonance test series


http://www.highvoltage-test.com/